H.F. Hauff Company Inc.
Partner Product

Altrac

Cloud-managed frost protection

ALTRAC WIND MACHINE STATION (ST100)

H.F. Hauff Chinook Wind Machines

Advanced automation for frost protection, controlled from your phone or browser

Close-up of a Chinook tower fan: a tall white tower topped with a two-blade propeller against a blue sky

What is the system?

Altrac ST100 Station

A rugged, weather-resistant cellular telemetry unit mounted directly to your Chinook tower.

WH111 Wiring Harness

An engineered plug-and-play assembly that bridges the Altrac controller with the Chinook's standard Murphy PV101 digital gauge panel.

Altrac Cloud Dashboard

An intuitive control suite for start/stop triggers, engine health indicators and real-time operational feedback from anywhere.

Turns autostart frost towers into fully automated, cloud-managed assets.

How it connects to your Chinook tower

Chinook engine ECU

Ground-level engine of the tower supplies the diagnostic data.

WH111 harness

Taps Port B of the Murphy PV101 digital panel over Modbus.

Altrac ST100

Cellular telemetry unit mounted on the tower.

Cloud dashboard

Control and monitor from a mobile app or web browser.

1 minCloud diagnostics refresh every minute
Port BDirect Modbus tap into the engine ECU
3 waysPhone calls, texts or push notifications

Five pillars of digital supervision

Altrac acts as an advanced digital supervisor over the ground-level engine of the Chinook tower.

1

Direct Modbus ECU Integration

The harness taps Port B of the Murphy PV101 to pull high-precision diagnostics straight from the engine ECU.

2

Dynamic Temperature Autostart

Change start/stop temperatures globally or per machine from a smartphone as buds develop.

3

RPM & Structural Integrity Defense

Tracks RPM and load; flags fan-blade or driveline shifts and can trigger a protective shutdown.

4

Switch Position Interlocking

Alerts management if a MAN-OFF-AUTO switch is left in OFF or MANUAL before a frost event.

5

Instantaneous Telemetry & Smart Alerts

Updates every minute; calls, texts or push alerts for startup, low battery voltage and fuel drops.

Operational outcomes for growers

Labor & Crew Efficiency

Eliminates physical 'frost runs' during freezing hours. Managers monitor the whole ranch from home, so crews stay rested and deploy only when necessary.

Fuel Conservation

Targeted engine shutoff at sunrise or the exact minute an inversion layer disperses, drastically reducing fuel costs.

Asset Protection

Immediate 'Battery Disconnect' and 'Low Voltage' notifications safeguard machinery from field theft and unexpected battery drainage.

Seasonal Data Logging

Downloadable Excel reports track exact runtime metrics and historical temperature curves to guide seasonal maintenance.

Dimensioned drawing of the Altrac controller: front view and bottom view of the hinged enclosure with its control line
Hinged, latching enclosure with the Altrac logo on the lid; the control line exits through a cable gland at the bottom.

Altrac controller: compact by design

5.906"Height
150 mm
3.917"Width
99.5 mm
2.776"Depth
70.5 mm
18 ftControl line
5.5 m cable
MOBILE APP

Monitor your wind machines from your phone

  • Fleet view
    All wind machines at a glance, each showing its current temperature.
  • Machine detail
    Controller state, machine state, RPM, air temperature, battery voltage and fuel level.
  • Temperature history
    A one-day chart of temperature and machine activity.
Altrac mobile app on two phones: a wind machine detail screen with a one-day temperature chart, and a fleet view listing each wind machine with its current temperature

Specifications

Operating voltageDesigned to operate within a standard 12VDC agricultural machinery electrical framework. Includes integrated firmware protections that enter a low-power standby mode during long out-of-season periods to mitigate parasitic battery drain.
Environmental protectionEnclosed within an impact-resistant, industrially sealed, UV-stabilized weather enclosure engineered to endure structural engine vibration and sustained freezing agricultural field conditions.
Control interfaceEmploys an integrated high-flexibility wiring trunk terminating in an industry-standard, heavy-duty automotive-grade 12-Pin Deutsch Connector (Part Number: AT06-12S).
Display connectionPlugs directly into open communication Slot 'B' on the rear panel of the Murphy PV101 gauge display.

For wiring and installation details, contact H.F. Hauff.

Manual

Altrac image gallery

Close-up of a Chinook tower fan with a two-blade propeller against a blue sky
Tower fan close-up
A Chinook tower fan on site, standing on open ground with the control enclosure at the base of the tower
Fan on site
Dimensioned drawing of the Altrac controller enclosure
Controller drawing
Altrac mobile app screens showing a wind machine detail view and a fleet view
Altrac mobile app
A control unit with a digital gauge display mounted on a wind machine engine
Engine-mounted control unit

Frost protection that keeps working while you rest

1Plug-and-playInstalls on H.F. Hauff towers through the WH111 harness and Murphy PV101 panel.
2Control from anywhereStart, stop and tune temperatures from a mobile app or web browser.
3Fewer frost runsRemote monitoring, smart alerts and sunrise shutoff save labor and fuel.

Altrac Wind Machine Station (ST100) + H.F. Hauff Chinook Wind Machine

Contact Us